Chi tiết tính năng :
|
• Có 8 mạch đầu vào loại B có thể thiết lập thành 4 mạch vào loại A |
| Xuất xứ : Canada |
| Bảo hành : 12 Tháng |
Sản phẩm cùng loại :
-
Báo cháy Hochiki HCP202
• Hochiki’s HCP-202 Fire Alarm Control Panel is a microprocessor based unit designed for small to medium commercial
• institutional and industrial occupancies. Fully configurable using DIP switches
• It enables the user to configure the system to meet their specific requirements.
• The HCP-202 comes standard with 2 Class B (Style B) Initiating Circuits which may be configured as 1 Class A (Style D) circuits.
• In addition it comes equipped with 2 Class A/B (Style Z/Y) indicating circuits which are each rated at 1.25 amps. The panel also includes a 2.75 Amp.
• Power Supply which powers the system and supplies a 4-wire resettable regulated smoke power supply of 24 VDC 100mA maximum.
• The HCP-202 utilizes a simple DIP switch configuration for programming initiating and indicating circuits as well as the enabling and disabling of system functions such as Signal Silence,
• Fire Drill and Auxiliary Disconnect. In addition the HCP-202 allows for Alarm Verification on the Initiating circuits.
• The Indicating circuits may be configured as Silenceable or Non-Silenceable with the audibles configured for Steady, March-Time,
• Temporal Code, or California Code. The cabinet is available in a beige color for the Canadian market and a red exterior for the
• International markets. A Fire Retardant Lexan Window in the hinged door allows for viewing of the status LEDs. It comes with a durable CAT-30 lock and key.
• Space is provided for up to 10 AH batteries.SPECIFICATIONS
• Primary Input Power 120 volts, 60 Hz, 1 Amps
• Indicating Current 24VDC unfiltered, 2.5Amps
• Standby Power 24VDC Standby Batteries
• Charging Capability 4 – 6.5 AH Batteries
• Dimensions: 12 3/4”H x 13 3/4”W x 3 1/8”DSTANDARD FEATURE
• 2 Class B (Style B) Initiating Circuits which may be configured as 1 Class A (Style D) circuits.
• 2 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.25 Amps max. per
circuit.)
• Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audibles may be
configured as Steady, Temporal Code, California Code or March Time
• Selectable Alarm Verification on Initiating Circuits
• Output for 4-wire resettable regulated smoke power supply of 24 VDC 100mA maximum
• Output for RTI or Remote Annunciators of 24VDC, 300 mA max, unfiltered
• Built-in Walk Test operation
• Auxiliary relay contacts for Common Alarm, Common Trouble and Common Supervisory. If no
Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay.
• 2.75 Amp Power Supply
• Easy configuration via DIP switchesXuất xứ : Canada Bảo hành : 12 Tháng Call
-
Báo cháy Hochiki HCP-204
• Hochiki’s HCP-204 Fire Alarm Control Panel is a microprocessor based unit designed for small to medium commercial
• Institutional and industrial occupancies. Fully configurable using DIP switches
• It enables the user to configure the system to meet their specific requirements.
• The HCP-204 comes standard with 4 Class B (Style B) Initiating Circuits which may be configured as 2 Class A (Style D) circuits.
• In addition it comes equipped with 2 Class A/B (Style Z/Y) Indicating circuits which are each rated at 1.25 amps.
• The panel also includes a 2.75 Amp Power Supply which powers the system and supplies a 4-wire resettable regulated smoke power supply of 24 VDC 100mA maximum.
• The HCP-204 utilizes a simple DIP switch configuration for programming initiating and indicating circuits as well as the enabling and disabling of system functions such as Signal Silence
• Fire Drill and Auxiliary Disconnect. Some predefined Initiating circuits can optionally be configured as Waterflow or Latching/Non-Latching Supervisory.
• In addition the HCP-204 allows for Alarm
• Verification on the initiating circuits. The Indicating circuits may be configured as Silenceable or Non-Silenceable with the audibles configured for Steady
• March-Time, Temporal Code, or California Code. The HCP-204 is equipped with auxiliary relay contacts for Common Alarm, Trouble and Supervisory.
• If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay.
• The cabinet is available in a beige color for the Canadian market and a red exterior for the and International markets.
• A Fire Retardant Lexan Window in the hinged door allows for viewing of the status LEDs. It comes with a durable CAT-30 lock and key. Space is provided for up to 10 AH batteries.
STANDARD FEATURES:
• 4 Class B (Style B) Initiating Circuits which may be configured as 2 Class A (Style D) circuits.
• 2 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.25 Amps max. per circuit.)
• Each Indicating Circuit can be configured as Silenceable or Non-Silenceable.
• Audibles may be configured as Steady, Temporal Code, California Code or March Time
• Selectable Alarm Verification on Initiating Circuits
• Output for 4-wire resettable regulated smoke power supply of 24 VDC 100mA maximum
• Output for RTI or Remote Annunciators of 24VDC, 300 mA max, unfiltered
• Built-in Walk Test operation
• Auxiliary relay contacts for Common Alarm, Common Trouble and Common Supervisory
• If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay.
• 2.75 Amp Power Supply
• Easy configuration via DIP switchesXuất xứ : Canada Bảo hành : 12 Tháng 455 USD
-
Báo cháy Hochiki HCP204E
• Hochiki’s HCP-204E Fire Alarm Control Panel is a microprocessor based unit designed for small to medium commercial
• Institutional and industrial occupancies.Fully configurable using DIP switches,
• It enables the user to configure the system to meet their specific
• Requirements. The HCP-204E comes standard with 4 Class B (Style B)
• Initiating Circuits which may be configured as 2 Class A (Style D) circuits.
• In addition it comes equipped with 2 Class A/B (Style Z/Y) Indicating Circuits which are each rated at 1.7 amps.
• The HCP-204E can be expanded up to 8 Class B (Style B) or 4 Class A (Style D)
• Initiating Circuits and 4 Class A/B (Style Z/Y)
• Indicating Circuits with the addition of an HDM-204 Adder Zone Module.
• The panel also includes a 6 amp power supply which powers the system and supplies a 4-wire resettable
• Regulated smoke power supply of 24 VDC 100mA maximum.
• The HCP-204E utilizes a simple DIP switch configuration for programming initiating
• Indicating circuits as well as the enabling and disabling of system functions such as Signal Silence,
• Fire Drill and Auxiliary Disconnect.
• Some predefined Initiating Circuits can optionally be configured as Waterflow or Latching/Non-Latching Supervisory.
• In addition the HCP-204E allows for alarm verification on the Initiating Circuits.
• The Indicating Circuits may be configured as Silenceable or Non- Silenceable with audibles configured for Steady,
• March-Time, Temporal Code, or California Code.
• The HCP-204E is equipped with auxiliary relay contacts for Common Alarm,
• Trouble and Supervisory. If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay.
• The cabinet is available in a beige color for the Canadian market and a red exterior for the
• And International markets. A Fire Retardant Lexan Window in hinged door allows for viewing of the.status LED’s.
• It comes with a durable CAT-30 lock and key. Space is provided for up to 10 AH batteries.STANDARD FEATURES
• 4 Class B (Style B) Initiating Circuits which may be configured as 2 Class A (Style D) circuits.
Expandable up to 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits
• 2 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.7 amps max. per
circuit.) Expandable up to 4 Class A/B (Style Z/Y) Indicating Circuits
• Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audibles may be
configured as Steady, Temporal Code, California Code or March TimeSPECIFICATIONS
• Output for RTI or Remote Annunciators of 24VDC, 300 mA max, unfiltered
• Built-in Walk Test operation
• Auxiliary relay contacts for Common Alarm, Common Trouble and Common Supervisory. If no
Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay
• 6 Amp Power Supply
• Easy configuration via DIP switchesModel Description Fire Alarm Control Panel
• HCP-204E Four expandable to Eight Zone Microprocessor Based Fire Alarm Control Panel comes with 4 Class
• B (Style B) or 2 Class A (Style D) Initiating Circuits, 2 Class A/B (Style Z/Y) Indicating Circuits and a
• 6 amp power supply. Expandable up to 8 Class B (Style B) Initiating Circuits or 4 Class A (Style D)
• 4 Class A/B (Style Z/Y) Indicating Circuits. Allows for one HDACT-100 Digital Communicator or
• One HPR-100 Polarity Reversal Module. Also allows for one HRM-204 or HRM-208 Auxiliary Relay
• Module. Red enclosure comes with keylock door.
• HRTI-1 Remote Trouble IndicatorAdder Modules
• HDM-204 Four Class B (Style B) or Two Class A (Style D) Initiating Circuit and 2 Class A/B (Style Z/Y)
• Indicating Circuit Module
• HDACT-100 Digital Alarm Communication Transmitter/Dialer Module
• HPR-100 Polarity Reversal/City Tie Module
• HRM-204 Auxiliary Relay Module comes with 4 configurable relays
• HRM-208 Auxiliary Relay Module comes with 8 configurable relaysRemote Annunciator
• HRAM-208 Remote Multiplex Annunciator comes with Common Control Features,
• Indicators and 8 Bi-Colored LED’s
• Controls: Signal Silence, Buzzer Silence, Lamp Test & System Reset
• Indicators: A.C. On, Common Trouble & Signal SilenceXuất xứ : Canada Bảo hành : 12 Tháng 500 USD